4-Pin LEMO-Compatible to 3-Lead 4.0mm ECG Female Snap Cable

Shielded 3-lead ECG cable with a 4-pin push-pull device connector and three 4.0mm female snap interfaces for compatible ECG and patient-monitoring equipment | Custom pinout & OEM/ODM available

The Heymed Medical 4-Pin LEMO-Compatible to 3-Lead ECG Snap Cable is designed for compatible ECG monitors and patient-monitoring equipment requiring a secure multi-pin device interface and three electrode connections.

The cable combines a 4-pin push-pull device connector with three 4.0mm female ECG snap leads and a shielded cable structure for device-to-electrode connectivity.

Heymed Medical supports customization of the pin assignment, cable length, lead configuration, snap interface, shielding structure, color, labeling and packaging for OEM/ODM projects.

4-Pin LEMO-Compatible to 3-Lead 4.0mm ECG Female Snap Cable
4-Pin LEMO-Compatible to 3-Lead 4.0mm ECG Female Snap Cable
4-Pin LEMO-Compatible to 3-Lead 4.0mm ECG Female Snap Cable
4-Pin LEMO-Compatible to 3-Lead 4.0mm ECG Female Snap Cable

Solutions & Applications

Custom 3-Lead ECG Connectivity for Patient-Monitoring Equipment

The 4-Pin to 3-Lead ECG Snap Cable provides configurable connectivity between compatible ECG monitors, patient-monitoring equipment and electrode accessories. The push-pull device interface connects to three separate 4.0mm female snap leads through a shielded cable structure.

For OEM/ODM projects, connector series, pin assignment, cable length, lead configuration, shielding structure and snap interface can be developed according to the finished-device requirements.

Heymed Medical supports device interface review, pinout confirmation, cable structure development, prototype sampling, continuity testing and volume manufacturing.

Product Specifications

Medical-grade auricular stimulation cable specifications for healthcare and neuromodulation therapy applications.

Product Type
3-Lead ECG Electrode Cable
Device-Side Connector
4-Pin LEMO-Compatible Push-Pull Connector
Electrode-Side Connector
3 × 4.0mm Female Snap
Number of Leads
3 Leads
Cable Structure
24AWG Shielded Multi-Lead Cable
Cable Diameter
Approx. 2.5mm
Cable Length
Customizable
Pin Assignment
Customized According to Device Requirements
Compatible Equipment
ECG and Patient-Monitoring Equipment
Quality Inspection
Pinout, Continuity, Snap Fit, Connector Fit and Visual Inspection
Quality Management System
Production Managed Under ISO 13485 and ISO 9001
Documentation Support
Drawings, Inspection Records and Project-Specific Compliance Documents Available
OEM / ODM
Supported

4-Pin LEMO-Compatible to 3-Lead 3.9/4.0mm ECG Snap Cable

This shielded ECG lead-wire assembly provides a 1-to-3 connection between compatible patient-monitoring equipment and snap-style electrode interfaces. The device side uses a 4-pin LEMO-compatible locking push-pull connector, while the electrode side terminates in three 3.9/4.0mm female snap connectors.

The cable is designed for OEM and ODM projects where connector keying, pin assignment, cable length, branch dimensions and electrode-side connections need to match a specific monitoring system. Heymed Medical can support connector review, pinout confirmation, cable structure development, prototyping and controlled production.

4-pin locking push-pull ECG cable with color-coded female snap electrode connectors

Locking Push-Pull Interface for Patient Monitoring Equipment

The equipment-side connector uses a locking push-pull structure designed to provide a detachable connection while maintaining mechanical retention after mating. This type of interface is useful for monitoring equipment where secure connection and repeatable cable handling are important.

Connector appearance alone does not confirm compatibility. Connector series, shell dimensions, keying direction, contact layout, mating depth and electrical pin assignment must all correspond to the target equipment.

For projects using a different device-side architecture, a USB-C 90° to 3-Lead 4.0mm ECG Female Snap Electrode Cable provides another example of how the same electrode-side concept can be adapted around a different equipment interface.

Independent 3.9/4.0mm Female Snap Electrode Connections

The 1-to-3 lead architecture separates the equipment-side connection into three individual electrode leads. Each branch is designed around a 3.9/4.0mm female snap interface for mating with compatible electrode studs.

Lead identification, branch dimensions and channel sequence can be configured according to the customer's approved wiring definition. Nominal snap diameter alone does not guarantee compatibility, so mating geometry, insertion depth and retention characteristics should be checked against the intended electrode before production.

For products requiring another compact equipment-side connector, the 4-Pin Spring-Loaded Contact to 3-Lead 4.0mm ECG Snap Cable provides an alternative device-interface structure for related monitoring applications.

Shielded Cable Structure for Biosignal Connection

The standard product uses a shielded 24AWG cable structure with a nominal cable diameter of approximately 2.5mm. Shielding can be incorporated into the cable design to help manage external electrical interference within the complete monitoring system.

Final signal performance depends on more than the cable alone. Shield termination, grounding method, conductor arrangement, cable length, equipment input design and the surrounding electrical environment all influence the complete signal path.

Cable jacket material, shielding construction, conductor specification and strain relief can therefore be reviewed together with the finished-device requirements rather than treated as fixed independent parameters.

Pinout Must Match the Actual Monitoring Device

A 4-pin connector does not automatically determine how the individual ECG leads should be wired. Devices with mechanically similar connectors may use different contact assignments, signal definitions or channel sequences.

Heymed Medical can review device drawings, PCB definitions, pinout tables, connector specifications or an existing reference cable before prototype development. The relationship between the device-side contacts and individual snap leads can then be confirmed according to the approved equipment architecture.

Additional ECG connector structures, channel configurations and monitoring lead wires can also be reviewed through our ECG Cables & Lead Wires range.

Key Customization Options

Device connector: Connector series, shell size, keying, mating structure and project-specific interface requirements.

Pin assignment: Device-side contact mapping and individual electrode-channel definition according to the approved drawing.

Electrode interface: 3.9/4.0mm female snap geometry or other project-specific electrode connectors.

Cable configuration: Main cable length, individual branch length, breakout position and routing can be customized.

Cable construction: Conductor specification, shielding, jacket material, strain relief and overmold structure can be reviewed according to the target equipment.

Identification and packaging: Lead colors, labels, markings, logo and OEM/ODM packaging can be developed according to project requirements.

Developed as a Complete Device-to-Electrode Cable Assembly

For patient-monitoring equipment, the device connector, cable construction and electrode-side interface should be considered as one complete connection system. Mechanical fit alone is not sufficient; pinout, channel mapping, shielding and snap compatibility should all be reviewed together.

Where a project requires a different connector, lead count or cable architecture, Heymed Medical can develop the assembly through our Custom Medical Cable Assemblies engineering and manufacturing capability.

From Engineering Sample to OEM/ODM Production

Development can begin from a monitoring-device model, connector drawing, pinout definition, cable specification or existing reference sample. Our engineering team can review the electrical and mechanical interface before preparing a prototype.

During sample development, connector mating, keying, pin-to-lead continuity, snap engagement, cable dimensions, shielding structure and strain relief can be checked against the approved project requirements.

Once the configuration is confirmed, conductor materials, cable construction, molding, lead identification, inspection and packaging can be transferred into repeatable OEM/ODM production.

Custom Medical Cable Manufacturing

We provide OEM and ODM medical cable assembly services for neuromodulation therapy device manufacturers and healthcare brands worldwide.

Frequently Asked Questions (FAQ)

Resolve your concerns in advance — stress-free communication, efficient coordination

Q1

What is a 4-pin to 3-lead ECG snap cable?

It is a reusable ECG cable assembly that connects a compatible monitor through a 4-pin push-pull device interface and provides three separate electrode leads with female snap connectors.

Q2

What connectors are used on this ECG cable?

The referenced configuration uses a 4-pin LEMO-compatible push-pull connector on the device side and three 4.0mm female ECG snap connectors on the electrode side.

Q3

Is this a shielded ECG cable?

Yes. The referenced configuration uses a 24AWG shielded cable structure with an approximate main cable diameter of 2.5mm.

Q4

Can the pin assignment and cable length be customized?

Yes. Connector series, pin assignment, cable length, lead configuration, shielding structure and electrode-side snap interfaces can be customized according to the target ECG or patient-monitoring device.

Q5

Can Heymed Medical develop this ECG cable from a device drawing or existing sample?

Yes. Customers can provide monitor interface drawings, connector specifications, pin definitions, existing cable samples or reference photos for engineering evaluation and prototype development.

Medical & Wellness Products and Connectivity Solutions

Medical & Wellness Products and Connectivity Solutions

Heymed Medical develops and manufactures OEM/ODM medical and wellness products for patient monitoring, EEG and brain monitoring, tVNS/taVNS neuromodulation, physiotherapy and rehabilitation, diagnostic equipment, and medical docking and charging applications.

Our portfolio includes tVNS/taVNS devices, auricular and ear clip electrodes, dry and wet EEG electrodes, EEG caps, ECG/EMG lead wires and electrodes, TENS/EMS lead wires and accessories, custom medical cable assemblies, Pogo Pin connectors, and charging docks.

Bring Your Medical Product to Production with Confidence

Work with Heymed Medical on OEM/ODM development and controlled manufacturing for tVNS and taVNS products, EEG electrodes, medical lead wires, custom cable assemblies, and medical docking and charging products—from engineering samples and validation to volume production.

Share Your Project Requirements

Tell our engineering team about your product application, device interface, performance targets, compliance needs, and expected quantity. We will review your information and contact you to discuss technical feasibility, customization options, and recommended next steps.

  • Product type and intended application
  • Technical and performance requirements
  • Electrode, cable, connector, or interface specifications
  • Device model or compatibility requirements
  • Drawings, pinout diagrams, samples, or reference photos
  • Compliance or certification requirements

Tip: A drawing, device interface photo, pinout diagram, or reference sample can help our engineering team evaluate your project more accurately and efficiently.